Genuine Ramset 800-76-50 upgrade kit assembly — Ramset’s “5-12 Upgrade Kit,” the current ETL control board set packaged to replace the Intelligate electronics in an older RAM slide or swing gate operator. It is the path Ramset gives for operators whose original board is no longer available.
When to use the kit instead of a board. The pre-2016 800-63-00 Intelligate board is still available, so a like-for-like swap on an older operator does not need the kit. The kit is for the first-generation UL325 operators whose 800-63-00-UL board Ramset has discontinued, and for anyone bringing an older operator up to the current standard. Call us with the operator model and the number on the existing board before ordering; the ETL set is AC/DC-specific.
Specifications
| Part number | 800-76-50 |
|---|---|
| Ramset description | 5-12 Upgrade Kit Assembly |
| Replaces | 800-63-00-UL (discontinued) |
| Related boards | 800-65-01 logic, 800-65-02 AC driver, 800-65-05 DC driver |
| Condition | Genuine Ramset OEM, new |
Ramset control boards, by generation
Ramset’s RAM slide and swing operators have used three generations of control electronics. Read the number on the board in your operator before ordering:
| Board | What it is |
|---|---|
| 800-63-00 | Intelligate control board, domestic, for operators built before the 2016 UL325 changeover. Also numbered 50-036C; replaces the 5-12H |
| 800-63-00-INTL | Intelligate control board, international version, pre-2016 |
| 800-63-00-UL | Intelligate board for the first UL325 (2016) operators — discontinued by Ramset |
| 800-65-01 | ETL logic board, current — specify AC or DC |
| 800-65-02 | ETL AC driver board, pairs with the 800-65-01 on AC operators |
| 800-65-05 | ETL DC driver board, pairs with the 800-65-01 on DC operators |
| 800-76-50 | 5-12 upgrade kit assembly — the ETL board set to bring an older operator up to date |
After fitting
The new boards arrive unprogrammed. Set the limits and force, relearn every transmitter, re-enter timer, loop and accessory settings, and re-test every entrapment protection device before returning the gate to service.
Fit surge protection at the same time. Storm damage is a leading cause of gate operator board failure. If this board died after a storm, the replacement is at the same risk unless the installation is protected.
Related
RAM 30 · RAM 300 · RAM 302 · RAM 100 · RAM 1000 · RAM 5200 · all Ramset parts
Not sure which board you need? Send a photo of your existing board to parts@gatehousesupplies.com or call 866-965-5599. We would rather confirm it than have you fit the wrong board.