Specifications
| Part number | 800-63-00-INTL |
|---|---|
| Ramset description | Control Board, Intelligate, International, pre-UL325 2016 |
| Fits | Ramset RAM slide and swing operators built before 2016, international build |
| Condition | Genuine Ramset OEM, new |
Ramset control boards, by generation
Ramset’s RAM slide and swing operators have used three generations of control electronics. Read the number on the board in your operator before ordering:
| Board | What it is |
|---|---|
| 800-63-00 | Intelligate control board, domestic, for operators built before the 2016 UL325 changeover. Also numbered 50-036C; replaces the 5-12H |
| 800-63-00-INTL | Intelligate control board, international version, pre-2016 |
| 800-63-00-UL | Intelligate board for the first UL325 (2016) operators — discontinued by Ramset |
| 800-65-01 | ETL logic board, current — specify AC or DC |
| 800-65-02 | ETL AC driver board, pairs with the 800-65-01 on AC operators |
| 800-65-05 | ETL DC driver board, pairs with the 800-65-01 on DC operators |
| 800-76-50 | 5-12 upgrade kit assembly — the ETL board set to bring an older operator up to date |
Is the board actually the problem?
| Symptom | Check first |
|---|---|
| Operator dead, no board lights | Incoming power, the fuse and the transformer before the board |
| Powers up but ignores every input | The board |
| Board lights but the motor will not run | On the ETL generation, the driver board before the logic board; then the motor, capacitor and contactor |
| Gate opens but will not close | A loop detector, photo eye or edge holding it open, not the board |
| Failed after a storm | Surge damage — the board |
| Burnt smell, scorching or a bulged capacitor on the board | The board — replace it |
After fitting
The new board arrives unprogrammed. Set the limits and force, relearn every transmitter into the 800-64-50 receiver terminal, re-enter timer, loop and accessory settings, and re-test every entrapment protection device before returning the gate to service.
Fit surge protection at the same time. Storm damage is a leading cause of gate operator board failure. If this board died after a storm, the replacement is at the same risk unless the installation is protected.