Genuine DoorKing 4602-010 control board — the circuit board for the DoorKing 9100 and 9150 slide gate operators, and the most replaced part on both. The 9100 and 9150 share this board, their 18-pin terminal and their pulley; the housing, clutch pad and main shaft differ.
Two versions — choose your Date of Manufacture above. DoorKing revised this board in January 2016. The base number is 4602-010; the suffix identifies the version: -018 for operators built January 2016 or later (current, with the UL325 monitored-device input) and -012 for operators built before January 2016. You do not order those numbers separately: pick the date from the dropdown. If you are unsure, read the number on the board currently fitted — it will end in -012 or -018.
Not the 9050 or 9070. Those take the 4702-010. Check the model on the cabinet label before ordering.
Specifications
| Part number | 4602-010 (-012 or -018 by build date) |
|---|---|
| DoorKing description | PCB, Slide Gate Operator |
| Fits | DoorKing 9100, 9150 |
| Condition | Genuine DoorKing OEM, new |
Is the board actually the problem?
| Symptom | Check first |
|---|---|
| Operator dead, no board lights | Incoming power at the terminals and the fuse before the board |
| Powers up but ignores every input | The board |
| Failed after a storm | Surge damage — the board, plus the 4001-093 MOV and the 2901-002 18-pin terminal, which usually show heat damage too |
| Board lights but the motor will not run | Motor, capacitor and the terminal strip before the board |
| Gate opens but will not close | A loop detector or photo eye holding it open, not the board |
| Burnt smell, scorching or a bulged capacitor on the board | The board — replace it |
After fitting
The new board arrives unprogrammed. Set the travel limits and force, relearn every remote and transmitter, and re-enter timer, loop and accessory settings before returning the gate to service. Re-test every entrapment protection device before handing the gate back.
Fit surge protection at the same time. Storm damage is a leading cause of gate operator board failure. If this board died after a storm, the replacement is at the same risk unless the installation is protected.
Common questions
Which date do I choose? Read the number on your existing board. -018 means January 2016 or later; -012 means earlier. If the board is unreadable, the operator’s serial label gives the build date.
Is this genuine? Yes, genuine DoorKing OEM.
Related
DoorKing 9100 parts · 9150 parts · 9050 parts (4702-010 board) · safety equipment, sensors & loops
Not sure which board you need? Send a photo of your existing board to parts@gatehousesupplies.com or call 866-965-5599. We install and service DoorKing slide gates and would rather confirm it than have you fit the wrong board. Since 1993.