Genuine LiftMaster K41-0073-000MC HD main control board — the logic board in all four of LiftMaster’s heavy-duty and industrial DC operators: the HDSW24UL swing and the HDSL24UL, IHSL24UL and INSL24UL slides. LiftMaster lists it as “Main Board, HD Gates” on the HDSL24UL and “Control Board” on the IHSL/INSL. It runs the limits, timers, radio, safety inputs and the display; the motor is driven by a separate board (below).
How to identify it. The service kit is K41-0073-000MC. The board inside may be printed K41-0073-000, K41-0094-000 (the number the HDSW24UL manual uses for the factory-fitted board) or carry a sticker reading 001D9525-1CC / K1D9525-1CC. All of those are this board.
Specifications
| Part number | K41-0073-000MC (K41-0073-000) |
|---|---|
| LiftMaster description | HD Main Control Board |
| Also seen on the board | K41-0094-000, 001D9525-1CC / K1D9525-1CC |
| Fits | HDSW24UL, HDSL24UL, IHSL24UL, INSL24UL |
| Condition | Genuine LiftMaster OEM, new |
The boards in the HD and industrial family
LiftMaster’s four heavy-duty DC operators share most of their electronics. The table below is taken from the repair-parts pages of the HDSW24UL, HDSL24UL and IHSL24UL/INSL24UL manuals; the part you are on is in bold.
| Operator | Control board | Power board | Motor drive | Relay adapter | Expansion | EMI board | Rectifier |
|---|---|---|---|---|---|---|---|
| HDSW24UL swing | K41-0073-000MC (board printed K41-0094-000) | K41-0071-000 | K41-0095-000 | K41-0072-000 | K1D8387-1CC | K1D7078 | K41-0083-000 |
| HDSL24UL slide | K41-0073-000MC | K41-0071-000 | K41-0095-000 | K41-0072-000 | K1D8387-1CC | K1D7078 | K41-0083-000 |
| IHSL24UL industrial slide | K41-0073-000MC | combined, below | K41-0245-000 (power + motor drive) | K41-0072-000 | K1D8387-1CC | K1D7078 | K41-0083-000 |
| INSL24UL industrial slide | K41-0073-000MC | combined, below | K41-0244-000 (power + motor drive) | K41-0072-000 | K1D8387-1CC | K1D7078 | K41-0083-000 |
Is the main board actually the problem?
| Symptom | Check first |
|---|---|
| Gate slows, stops partway, reverses on its own, or dies in a power cut | The batteries. These operators run off two 29-NP712 12V 7AH batteries (or the pre-wired pair K74-30762); replace both together |
| Operator dead, no lights on any board | The transformer and the EMI board first — K41-0067-000 (HD swing and slide), K41-0241-000 (IHSL24UL), K41-0346-000 (INSL24UL) — then the K41-0083-000 bridge rectifier |
| Board lights and responds, but the motor will not run | The motor drive: K41-0095-000 on the HDSW24UL and HDSL24UL, K41-0245-000 (IHSL24UL) or K41-0244-000 (INSL24UL), not the main board |
| Gate overruns or stops short | The limit system — K41-0092-000 APS on the HDSW24UL, K41-0051-000 APE on the HDSL24UL; K41-0247-000 limit system and K41-0246-000 encoder on the IHSL/INSL |
| Loops or accessories not responding | The K1D8387-1CC expansion board or the K41-0072-000 relay adapter, then the device |
| No warning tone before the gate moves | The alarm: K41-0068-000 (HDSW24UL, HDSL24UL) or K41-0248-000 (IHSL/INSL) |
| Powers up but ignores every input | This board |
| Burnt smell, scorching or a bulged capacitor on this board | This board — replace it |
After fitting
Photograph the harness connections before removing the old board and reconnect the new one the same way. Then set the limits and force, relearn every remote, re-enter timer, loop and accessory settings, and re-test every entrapment protection device to UL325 before returning the gate to service.
Fit surge protection at the same time. Storm damage is a leading cause of gate operator board failure. If this board died after a storm, the replacement is at the same risk unless the installation is protected.
Related
HDSW24UL parts · HDSL24UL parts · IHSL24UL parts · INSL24UL parts · safety equipment, sensors & loops
Not sure which board you need? Send a photo of your existing board to parts@gatehousesupplies.com or call 866-965-5599. We would rather confirm it than have you fit the wrong board.