Genuine LiftMaster K41-0071-000 HD power board — the DC power board in the HDSW24UL heavy-duty swing and HDSL24UL heavy-duty slide operators. It takes the rectified supply and the batteries and feeds the main control board and the motor drive board. The industrial IHSL24UL and INSL24UL do not use it; their power stage is built into the BLDC motor drive board.

Specifications

Part numberK41-0071-000
LiftMaster descriptionHD Power Board
FitsHDSW24UL, HDSL24UL
KitAlso supplied inside K41-0097-000, the motor + motor drive + power board kit
ConditionGenuine LiftMaster OEM, new

The boards in the HD and industrial family

LiftMaster’s four heavy-duty DC operators share most of their electronics. The table below is taken from the repair-parts pages of the HDSW24UL, HDSL24UL and IHSL24UL/INSL24UL manuals; the part you are on is in bold.

OperatorControl boardPower boardMotor driveRelay adapterExpansionEMI boardRectifier
HDSW24UL swingK41-0073-000MC (board printed K41-0094-000)K41-0071-000K41-0095-000K41-0072-000K1D8387-1CCK1D7078K41-0083-000
HDSL24UL slideK41-0073-000MCK41-0071-000K41-0095-000K41-0072-000K1D8387-1CCK1D7078K41-0083-000
IHSL24UL industrial slideK41-0073-000MCcombined, belowK41-0245-000 (power + motor drive)K41-0072-000K1D8387-1CCK1D7078K41-0083-000
INSL24UL industrial slideK41-0073-000MCcombined, belowK41-0244-000 (power + motor drive)K41-0072-000K1D8387-1CCK1D7078K41-0083-000

Is the power board actually the problem?

SymptomCheck first
Gate slows, stops partway, reverses on its own, or dies in a power cutThe batteries. These operators run off two 29-NP712 12V 7AH batteries (or the pre-wired pair K74-30762); replace both together
Operator dead, no lights on any boardThe transformer and the EMI board first — K41-0067-000 (HD swing and slide), K41-0241-000 (IHSL24UL), K41-0346-000 (INSL24UL) — then the K41-0083-000 bridge rectifier
Rectifier output present, main board deadThis board
Main board lights, motor will not runThe K41-0095-000 motor drive board, then this board
Batteries never chargeThis board, after confirming transformer and rectifier output
Burnt smell, scorching or a bulged capacitor on this boardThis board — replace it

After fitting

Photograph the harness connections before removing the old board and reconnect the new one the same way. Then set the limits and force, relearn every remote, re-enter timer, loop and accessory settings, and re-test every entrapment protection device to UL325 before returning the gate to service.

Fit surge protection at the same time. Storm damage is a leading cause of gate operator board failure. If this board died after a storm, the replacement is at the same risk unless the installation is protected.

Related

HDSW24UL parts · HDSL24UL parts · IHSL24UL parts · INSL24UL parts · safety equipment, sensors & loops

Not sure which board you need? Send a photo of your existing board to parts@gatehousesupplies.com or call 866-965-5599. We would rather confirm it than have you fit the wrong board.