Genuine LiftMaster K41-0072-000 relay adapter board — the relay output board shared by all four of LiftMaster’s heavy-duty and industrial DC operators: the HDSW24UL, HDSL24UL, IHSL24UL and INSL24UL. It carries the relay outputs the control board uses to switch external devices, and mounts beside the power board on the K41-0249-000 mounting plate.
Specifications
| Part number | K41-0072-000 |
|---|---|
| LiftMaster description | Relay Adapter Board, HD |
| Fits | HDSW24UL, HDSL24UL, IHSL24UL, INSL24UL |
| Condition | Genuine LiftMaster OEM, new |
The boards in the HD and industrial family
LiftMaster’s four heavy-duty DC operators share most of their electronics. The table below is taken from the repair-parts pages of the HDSW24UL, HDSL24UL and IHSL24UL/INSL24UL manuals; the part you are on is in bold.
| Operator | Control board | Power board | Motor drive | Relay adapter | Expansion | EMI board | Rectifier |
|---|---|---|---|---|---|---|---|
| HDSW24UL swing | K41-0073-000MC (board printed K41-0094-000) | K41-0071-000 | K41-0095-000 | K41-0072-000 | K1D8387-1CC | K1D7078 | K41-0083-000 |
| HDSL24UL slide | K41-0073-000MC | K41-0071-000 | K41-0095-000 | K41-0072-000 | K1D8387-1CC | K1D7078 | K41-0083-000 |
| IHSL24UL industrial slide | K41-0073-000MC | combined, below | K41-0245-000 (power + motor drive) | K41-0072-000 | K1D8387-1CC | K1D7078 | K41-0083-000 |
| INSL24UL industrial slide | K41-0073-000MC | combined, below | K41-0244-000 (power + motor drive) | K41-0072-000 | K1D8387-1CC | K1D7078 | K41-0083-000 |
Is the relay board actually the problem?
| Symptom | Check first |
|---|---|
| Gate runs, but a relay-driven accessory (lock, light, external device) never switches | The accessory’s own wiring and supply, then this board |
| Loops or monitored inputs not responding | The K1D8387-1CC expansion board, not this board |
| Gate does not run at all | The batteries, transformer and main board — this board does not stop the gate |
| Relay clicks but the device does not respond | The device and its wiring, not this board |
| Scorching or a burnt relay on this board | This board — replace it |
After fitting
Photograph the harness before removing the old board and reconnect the new one the same way. Re-test each relay-driven accessory before handing the gate back.
Fit surge protection at the same time. Storm damage is a leading cause of gate operator board failure. If this board died after a storm, the replacement is at the same risk unless the installation is protected.