GTO R5211-02 Pro Control Board - Linear SL25 Series Slide Gate Openers (GPX-SL25, SL25BE; 2016 On)

(No reviews yet) Write a Review
SKU:
R5211-02
Availability:
In Stock

GTO

$472.35
Condition:
New

Genuine GTO / Linear R5211-02 Pro control board — the post-2016 control board for the Linear Pro SL25 series slide gate openers (the GPX-SL25 and SL25BE builds; GTO reference 10019209).

Check the board before ordering. The R5211 family has three members that look alike: R5211 for the PRO swing operators, R5211-01 for the SL2000B/SL2200B and R5211-02 for the SL25 series. Read the full number, including the suffix, on the board currently fitted.

Specifications

Part numberR5211-02 (GTO 10019209)
FitsLinear Pro SL25 series — GPX-SL25, SL25BE — 2016 on
ConditionGenuine GTO / Linear OEM, new

Which GTO / Linear board do I have?

GTO, Linear PRO Access and Mighty Mule are one company, and the boards cross the brand names. Match on the operator model, and read the number on the board currently fitted:

OperatorLogic board
GTO / PRO SW2000XL, SW2500XL, SW3000XL, SW4000XLR5211
GTO / PRO SW3000XLS, SW4000XLSR5211
Older GTO / PRO 2000, 2500, 3000, 4000R5211
Mighty Mule FM500, FM502 (MM 500 series)R5211
GTO / PRO SW2000XLS, SW2002XLSR5722
Mighty Mule MM262, MM362, MM402, MM462, MMDIA30SR5722
Linear / GTO SL2000B, SL2200B slide (2016 on)R5211-01
Linear / GTO SL25 series slide (GPX-SL25, SL25BE; 2016 on)R5211-02
Mighty Mule MM371, MM372, MM571, MM572 (W)RP1007

Is the board actually the problem?

SymptomCheck first
Opener dead, no lights on the boardThe battery and its terminals, then the transformer or solar panel output, before the board
Gate runs slowly, stops partway or only works some of the timeA tired battery — these openers run off the battery and only charge from the transformer or panel
Remotes do nothing, the button on the board worksReprogram the remotes to the board first; then the remote batteries
Gate overruns or stops shortThe limit or rev counter sensing, not this board
Board lights but the motor does not runThe motor and its wiring, then the board
Failed after a storm or a lightning strikeSurge damage — the most common reason a GTO board gets replaced
Burnt smell, scorching or a bulged component on the boardThe board — replace it

After fitting

The new board arrives with an empty transmitter memory and default settings. Relearn every remote and keypad, set the open and close limits, the auto-close timer and the obstruction sensitivity, and re-test the safety devices before returning the gate to service.

Fit surge protection at the same time. Storm damage is a leading cause of gate operator board failure. If this board died after a storm, the replacement is at the same risk unless the installation is protected.

Related

all GTO parts

Not sure which board you need? Send a photo of your existing board to parts@gatehousesupplies.com or call 866-965-5599. We would rather confirm it than have you fit the wrong board.