Genuine GTO / Linear R5211-02 Pro control board — the post-2016 control board for the Linear Pro SL25 series slide gate openers (the GPX-SL25 and SL25BE builds; GTO reference 10019209).
Check the board before ordering. The R5211 family has three members that look alike: R5211 for the PRO swing operators, R5211-01 for the SL2000B/SL2200B and R5211-02 for the SL25 series. Read the full number, including the suffix, on the board currently fitted.
Specifications
| Part number | R5211-02 (GTO 10019209) |
|---|---|
| Fits | Linear Pro SL25 series — GPX-SL25, SL25BE — 2016 on |
| Condition | Genuine GTO / Linear OEM, new |
Which GTO / Linear board do I have?
GTO, Linear PRO Access and Mighty Mule are one company, and the boards cross the brand names. Match on the operator model, and read the number on the board currently fitted:
| Operator | Logic board |
|---|---|
| GTO / PRO SW2000XL, SW2500XL, SW3000XL, SW4000XL | R5211 |
| GTO / PRO SW3000XLS, SW4000XLS | R5211 |
| Older GTO / PRO 2000, 2500, 3000, 4000 | R5211 |
| Mighty Mule FM500, FM502 (MM 500 series) | R5211 |
| GTO / PRO SW2000XLS, SW2002XLS | R5722 |
| Mighty Mule MM262, MM362, MM402, MM462, MMDIA30S | R5722 |
| Linear / GTO SL2000B, SL2200B slide (2016 on) | R5211-01 |
| Linear / GTO SL25 series slide (GPX-SL25, SL25BE; 2016 on) | R5211-02 |
| Mighty Mule MM371, MM372, MM571, MM572 (W) | RP1007 |
Is the board actually the problem?
| Symptom | Check first |
|---|---|
| Opener dead, no lights on the board | The battery and its terminals, then the transformer or solar panel output, before the board |
| Gate runs slowly, stops partway or only works some of the time | A tired battery — these openers run off the battery and only charge from the transformer or panel |
| Remotes do nothing, the button on the board works | Reprogram the remotes to the board first; then the remote batteries |
| Gate overruns or stops short | The limit or rev counter sensing, not this board |
| Board lights but the motor does not run | The motor and its wiring, then the board |
| Failed after a storm or a lightning strike | Surge damage — the most common reason a GTO board gets replaced |
| Burnt smell, scorching or a bulged component on the board | The board — replace it |
After fitting
The new board arrives with an empty transmitter memory and default settings. Relearn every remote and keypad, set the open and close limits, the auto-close timer and the obstruction sensitivity, and re-test the safety devices before returning the gate to service.
Fit surge protection at the same time. Storm damage is a leading cause of gate operator board failure. If this board died after a storm, the replacement is at the same risk unless the installation is protected.