Genuine LiftMaster K001D8396-1 Logic 5 power board — the single-phase 115 / 230 V relay power board fitted beside the logic board in every Logic 5.0 commercial door operator on single-phase supply. It carries the motor relays (the K4 relay comes fitted) and feeds the logic board. It replaces the K001D8396 and the original K001D8072-1.
Check the phase before ordering. This board is single-phase only. Three-phase operators take the K001D8397 power board kit and 575 V units the K001D8397-1. The supply voltage and phase are on the operator data label.
Specifications
| Part number | K001D8396-1 |
|---|---|
| Replaces | K001D8396, K001D8072-1 |
| LiftMaster description | Power Board, 115 / 230 V, 1PH, L5 |
| Supply | Single phase, 115 or 230 V |
| Fits | All single-phase Logic 5.0 operators: T, GT, GH, H, HJ, J, SD, GSD, APT |
| Kit | Power board with K4 relay fitted |
| Condition | Genuine LiftMaster OEM, new |
Which operators use the K001D8396-1
| Operator family (single phase) | Parts page |
|---|---|
| T, GT, APT trolleys | T parts · GT parts · APT parts |
| GH, H hoists; HJ hoist jackshaft | GH parts · H parts · HJ parts |
| J jackshaft; SD, GSD slide door | J parts · SD parts · GSD parts |
Parts often replaced with it
K001D8395MC logic board · K79-15016-1 RPM sensor · K75-36913 e-box cover
Is the board actually the problem?
On a Logic 5 box the power board fails more often than the logic board. Check in this order:
| Symptom | Check first |
|---|---|
| Operator dead, nothing lights | Supply and fuses first; then this power board (it feeds the logic board) |
| Logic board lights, motor never runs or one relay never pulls in | This board — a failed relay is the usual fault |
| Motor runs the wrong way or will not stop | Limits and the logic board before this board |
| Board scorched after a storm | This board, and fit surge protection with it |
After fitting
Confirm the voltage jumper matches the supply (115 or 230 V) before powering up, then re-test the limits and entrapment protection.
Fit surge protection when you fit the board. Lightning and utility surges are the most common reason a commercial operator board is replaced, and a new board on the same unprotected supply is at the same risk. The MOV kit on the electrical box is the first line; a proper surge arrester on the supply is the second.
Related
T parts · J parts · all LiftMaster commercial door parts
Not sure which board you need? Send a photo of the number printed on your existing board to parts@gatehousesupplies.com or call 866-965-5599. We would rather confirm it than have you fit the wrong board.