Accessories, safety devices and field-installable kits for the LiftMaster Maxum industrial DC operators — models JDC, RJDC, JHDC and TDC. Everything below fits every Maxum unless a specific model or voltage is called out. Click any part number to go straight to that item.
Three things that catch people out on this platform:
The traffic lights need a relay card. Both RGL24LY and RGL-CTL require the AUXREL auxiliary relay board, which is sold separately. Ordering the light alone leaves you with nothing to switch it.
Loop detection is two parts. LPEXP is the input board and LOOPDETLM is the detector itself — you need both for a working loop.
Most heaters need a cover. HTR and HTR460 require either COVERDC or 001A3982 to be fitted. Only HTR120NC works without a cover, and it needs its own separate 120VAC feed.
Every Maxum operator ships with the CPS-U photo eye as standard. The rest are alternatives for longer ranges, wet or washdown environments, or edge-based protection. Monitored devices report their own health back to the operator; non-monitored devices do not, and the guide labels them clearly below.
| Part # | Description |
|---|---|
| CPS-U | Monitored dual-sided infrared photoelectric sensors, NEMA 1, range up to 30 ft — included as standard with every Maxum operator |
| LMTBUL | Monitored thru-beam photoelectric sensors, NEMA 4X, range up to 90 ft |
| LMRRUL | Monitored retro-reflective photoelectric sensors, NEMA 4X, range up to 50 ft |
| CPS-UN4 | Monitored thru-beam photoelectric sensors, NEMA 4, range up to 45 ft |
| CPS-RPEN4 | Monitored retro-reflective photoelectric sensors, NEMA 4, range up to 50 ft |
| CPS-OPEN4 | Monitored dual-sided photoelectric sensors, NEMA 4X, range up to 45 ft |
| LC36M | Monitored light curtain, 36 in. length, range up to 33 ft |
| OES-SD16 | Monitored optical edge system, sectional door, 16 ft length, NEMA 6 |
| OES-SD24 | Monitored optical edge system, sectional door, 24 ft length, NEMA 6 |
| OES-RD16 | Monitored optical edge system, rolling door, 16 ft length, NEMA 6 |
| CPS-EI | Edge interface, 4-wire monitored |
| 65-8202 | Non-monitored entrapment protection device — pneumatic 14 ft sensing edge extension, mod kit |
| 65-5202 | Non-monitored entrapment protection device — pneumatic 14 ft sensing edge with 2-wire take-up reel, mod kit |
Also compatible: any 2-wire monitored Miller Edge model carrying a T2 designator, or a 4-wire edge with a 10 kilohm resistor wired in series. The Miller Edge RBand wireless edge sensor system (RB-TX10 transmitter with RB-P-RX10C receiver) also works with those edge sensors.
The DCWALLCTL LCD controller ships with every new Maxum and is what you use for floor-level commissioning, limit setting and speed adjustment. The 02-series stations are simpler open/close/stop controls for additional operating positions.
| Part # | Description |
|---|---|
| DCWALLCTL | LCD wall controller — included with new Maxum operators |
| 02-101 | Single-button wall controller, NEMA 1 |
| 02-102 | 2-button wall controller, NEMA 1 |
| 02-103L | 3-button wall controller, NEMA 1 |
| 02-406 | 3-button outdoor wall controller with single key control, NEMA 4/12 |
| 02-403-N4XALD | 3-button outdoor controller, NEMA 4/4X/12 |
All of these are Security+ 2.0. The Maxum has a receiver built in; the 312HM and 412HM are for older mixed-frequency sites, and the STAR1000 is the choice where you need to manage a large remote population.
| Part # | Description |
|---|---|
| 811LMX | Programmable DIP switch single-button remote control |
| 891LMMC | Single-button remote control |
| 893MAX | Three-button remote control — controls up to 3 openers |
| 878MAX | Wireless keypad, 4-digit PIN code |
| 850LM | Universal receiver |
| STAR1000 | Commercial access control receiver — up to 1,000 remotes |
| 312HM | Universal radio receiver, 315 MHz |
| 412HM | Universal radio receiver, 390 MHz |
| 86LM | Antenna extension kit, 15 ft (4.6 m) |
| 86LMT | Antenna extension kit, 25 ft (7.6 m) |
| 100MAPS | Plug-in 100 mA power supply, 28 ft cord length |
Approval note: every transmitter above is approved for use in the USA and Canada only, with one exception — the 811LMX is additionally approved for Mexico, Colombia, Costa Rica and Puerto Rico.
Interlock switches are specific to the door type — sectional and rolling are different parts. Both traffic lights require the AUXREL relay board.
| Part # | Description |
|---|---|
| 50-13529 | Sectional door interlock switch (also known as 50450) |
| 50-12949 | Rolling door interlock switch (also known as 50401) |
| 50-HERK2 | Motion detector, 24V, 23 ft cable |
| 50-HERK-RC2 | Optional remote control for the 50-HERK2 motion detector |
| RGL24LY | Red/green traffic light — requires AUXREL card, sold separately |
| RGL-CTL | Hi-intensity red/green traffic light, compact, NEMA 4 — requires AUXREL card, sold separately |
| AUXREL | Auxiliary relay board, for switching auxiliary devices on and off — lights, bells, horn/strobes and similar |
| LPEXP | Loop detector input board — required together with LOOPDETLM |
| LOOPDETLM | Plug-in loop detector — required together with LPEXP |
Battery backup is included on the JDC and is capable-but-not-included on the RJDC, JHDC and TDC. A fully charged battery gives about 20 cycles within 48 hours of losing AC power. Without a heater the Maxum is rated to −4°F; with one, to −40°F.
| Part # | Description |
|---|---|
| DC7AH | 7 AH battery backup kit — compatible with all Maxum operators except NEMA 4X |
| HTR | Heater kit for 120/240V single and three phase operators — requires COVERDC or 001A3982 |
| HTR460 | Heater kit for 480V three phase operators — requires COVERDC or 001A3982 |
| HTR120NC | Heater kit for all Maxum operators, no cover required — needs a separate 120VAC supply |
| COVERDC | Operator cover for all Maxum wall-mount models |
| 001A3982 | Operator cover for 700 and 1200 operators |
| CHNGUARD | Chain guard kit for 2 in. output shafts |
| CHAINGUARD3IN | Chain guard kit for 3 in. output shafts |
The Maxum ships as a dedicated 120/240V SKU or a dedicated 480V SKU. Running one on 208V or 600V is done with a transformer kit, and the kit is sized to the operator's door weight.
| Part # | Description |
|---|---|
| XF208VAC7 | 208V transformer kit — for 700 operators |
| XF208VAC12 | 208V transformer kit — for 1200 and 2200 operators |
| XF600VAC7 | 600V transformer kit — for 700 operators |
| XF600VAC12 | 600V transformer kit — for 1200 and 2200 operators |
Sprocket changes are the sanctioned way to slow a Maxum down. Dropping from a 12-tooth to a 10-tooth operator sprocket reduces door speed roughly 20%, or lets you use a smaller door sprocket at the same speed.
| Part # | Description |
|---|---|
| 71-1550B10LGH | 10-tooth operator sprocket kit, 1 in. bore x 1/4 in. keyway — replaces the 12-tooth drive sprocket to reduce speed 20% |
| K41-0564-000 | 16-tooth operator sprocket kit, #41 chain — replaces the 20-tooth sprocket on TDC12 to reduce speed 20%; standard on TDC22 |
| JAN41 | #41 chain and sprocket mod kit for rolling sheet doors |
| CHAINTENSDC | 1 in. chain tensioner (spreader bar) |
| CHAINTENS125DC | 1.25 in. chain tensioner (spreader bar) |
| HOISTMOUNTMODDC | Mount bracket kit — converts an L5 GH mount for a JDC, RJDC or JHDC install |
| FOHMODDC | Front of hood mount bracket kit |
| ARK | Auto reconnect trolley kit — for TDC7 operators |
| K41-0156-000 | Cable tension monitor, left |
| K41-0157-000 | Cable tension monitor, right |
Trolley modification kits: LiftMaster publishes the full list of trolley kits — including dual trolley, auxiliary trolley and dual auxiliary trolley mod kits — separately from this manual. Call us with your door configuration and we will source the right one.
| What you need | What to order |
|---|---|
| Longest photo eye range on an open bay | LMTBUL, monitored thru-beam, up to 90 ft |
| Washdown or wet environment | NEMA 4X devices: LMTBUL, LMRRUL, CPS-OPEN4 |
| Protection along the door bottom, not across the opening | OES-SD16 or OES-SD24 for sectional, OES-RD16 for rolling |
| Operator running outdoors below freezing | HTR120NC (no cover needed), or HTR/HTR460 with COVERDC |
| Door needs to run slower | 71-1550B10LGH on jackshaft and hoist, K41-0564-000 on a TDC12 |
| Site supply is 208V or 600V | Transformer kit sized to your door weight |
| Traffic light at a dock or drive-through | RGL24LY or RGL-CTL, plus AUXREL |
| Vehicle detection loop | LPEXP and LOOPDETLM together |
| Door must run through a power outage | DC7AH — already included on JDC models |
JDC, RJDC & JHDC Maxum Jackshaft and Hoist Parts · TDC Maxum Trolley Operator Parts · Complete Maxum DC Operators
Not sure what fits? Have your full Maxum model number ready and give us a call — we work on these units every day.