LiftMaster 041-0136 Safety Sensor Kit (replaces 041A5034 / 41A5034) - Photo Eyes for LiftMaster, Chamberlain and Craftsman Openers 1997 to Present

(No reviews yet) Write a Review
SKU:
041-0136
Availability:
In Stock

Liftmaster

$47.83
UPC:
012381198368
Condition:
New

Videos Hide Videos Show Videos

Genuine LiftMaster 041-0136 safety sensor kit — the current replacement for the 041A5034 / 41A5034 photo eyes fitted to LiftMaster, Chamberlain and Craftsman garage door openers from 1997 onward. One sending eye (amber LED), one receiving eye (green LED), two-conductor wire, wire nuts and the mounting hardware. The eyes are the reversing safety device the opener checks before every close: when they are misaligned, dirty or dead the door will not close from the remote and only creeps down while the wall button is held.

Brackets. The 041-0136 eyes clamp to the bracket by the head of a carriage bolt — they have no bolt hole through them like the old 41A5034. On an opener that had the older eyes, order the 041-0155-000 bracket pair with the kit; on 2021-and-later openers the brackets already fit. Extension brackets for a wall-mount installation are the 041A5281-1.

Three ways to buy these eyes.

This page is the genuine LiftMaster eye kit, no brackets. If your brackets are bent, rusted or missing, the 041-0365-000 includes eyes and brackets together. If you want the cheapest working pair and your brackets are fine, there is an aftermarket eye kit — non-OEM, not made by LiftMaster, but a matched sending and receiving pair that fits the same 1997-to-current openers.

Specifications

Part number041-0136 (replaces 041A5034 / 41A5034; also fitted as 041A4373ATS on some units)
In the boxSending sensor with amber LED, receiving sensor with green LED, 2-conductor wire, 5 wire connectors, hardware
FitsLiftMaster, Chamberlain and Craftsman residential openers made from 1997 to the present — chain, belt, screw and wall-mount, AC and DC, Security+ through Security+ 3.0
Not forOpeners before 1997 (different sensor and terminals), commercial operators (see CPS and LMRRUL eyes)
ConditionGenuine LiftMaster, new

Which eyes?

OpenerOrder
LiftMaster / Chamberlain / Craftsman residential, 1997 to present041-0136 — this kit
Same, built before 2021 with the old-style bracket041-0136 plus 041-0155-000 brackets
Commercial door operators (Logic, Maxum)CPS Commercial Protector System eyes
Gate operatorsMonitored gate photo eyes — LMRRUL or LMTBUL

Are the eyes actually the problem?

Nine sensor complaints in ten are alignment or wiring. Check before you order:

SymptomCheck first
Door will not close from the remote, closes with the wall button heldThe eyes: an LED off or blinking means blocked, misaligned or a broken wire. Fix that before buying anything
Both LEDs steady, still will not closeThe wire run — staples through the insulation, or the terminals at the opener — then the eyes
Sending eye dead, receiving eye litWire to the sending eye, then the sending eye
Works at night, fails in afternoon sunSun in the receiving eye. Fit the sun hoods or swap the eyes so the receiver faces away from the sun
Eyes fine, opener still flashes 1-1 or 1-2Reversed or shorted sensor wires at the opener (1-2); reseat and check polarity
Eyes fine, no click when the remote is pressedThe logic board or the remote, not the eyes

Fitting

Unplug the opener. Mount both eyes no more than 6 in above the floor, facing each other across the opening, and wire them to the two sensor terminals on the opener (white and white-with-black). Plug in, and adjust until both LEDs are steady — the receiving eye's green LED flickers until the beam is aligned. Then run the reversal test.

Related

041-0155-000 brackets · 041A5281-1 extension brackets · all LiftMaster opener parts · Chamberlain opener parts · Craftsman opener parts

Not sure which eyes or brackets your opener takes? Send the model number from the label on the head and a photo of the existing eye to parts@gatehousesupplies.com or call 866-965-5599. We would rather confirm it than have you order twice.