Genuine LiftMaster K1D8052-1CC main control board — the second-generation board for LiftMaster’s linear actuator (arm-type) swing gate operators: the LA500 and LA500DC, the LA400DC and the LA412DC. LiftMaster lists it as “Main Board, LA500, LA400, LA412.” It sits in the plastic control box between the original metal-box boards and the current UL325 K1D8388-1CC.
Not for the U or UL models. The LA400U/UL, LA412U/UL and LA500U/UL take the K1D8388-1CC. Open the control box and read the number on the board; the model name on the arm is not enough.
Specifications
| Part number | K1D8052-1CC |
|---|---|
| LiftMaster description | Main Board, LA500, LA400, LA412 |
| Fits | LA500, LA500DC, LA400DC, LA412DC |
| Condition | Genuine LiftMaster OEM, new |
Which board does my operator take?
| Operator | Original | Second generation | UL325 (2016 on) |
|---|---|---|---|
| LA400 family | K001A6039 — LA400, metal box | K1D8052-1CC — LA400DC | K1D8388-1CC — LA400U, LA400UL |
| LA412 family | K001A6426-1 — LA412, metal box | K1D8052-1CC — LA412DC | K1D8388-1CC — LA412U, LA412UL |
| LA500 family | K1D7545CC — LA500, no longer available | K1D8052-1CC — LA500, LA500DC | K1D8388-1CC — LA500U, LA500UL |
Is the board actually the problem?
| Symptom | Check first |
|---|---|
| Gate slows, stops partway, reverses on its own, or dies in a power cut | The batteries. These operators run off two 29-NP712 12V 7AH batteries (or the pre-wired pair K74-30762); replace both together |
| Operator completely dead, no lights on the board | Transformer and receptacle before the board — on the LA400 family the K74-30763 transformer and K74-30941 fuse kit |
| Gate will not reset after an obstruction | The reset switch — K23-19380 on the LA400/LA412 families, K94-36408-1 on the LA500 |
| No response to remotes, wired controls work | The antenna or receiver module, not the board |
| Arm hums but the gate does not move | The actuator arm, not the board |
| Burnt smell, scorching or a bulged capacitor on this board | This board — replace it |
After fitting
Photograph the harness connections before removing the old board and reconnect the new one the same way. Then set the limits and force, relearn every remote, re-enter timer, loop and accessory settings, and re-test every entrapment protection device to UL325 before returning the gate to service.
Fit surge protection at the same time. Storm damage is a leading cause of gate operator board failure. If this board died after a storm, the replacement is at the same risk unless the installation is protected.
Related
LA400 parts · LA412 parts · LA500 parts
Not sure which board you need? Send a photo of your existing board to parts@gatehousesupplies.com or call 866-965-5599. We would rather confirm it than have you fit the wrong board.