Genuine Platinum Access BLGOC-2400 control board kit — the current main control board for Platinum's brushless DC gate operators: the BLSL840 and BLSL2250 slide operators and the BLSW814 and BLSW1016 swing operators. It is the direct replacement for the BLGOC-2000 and the discontinued BLGOC-2200, with the monitored entrapment-device inputs the UL325 standard requires: the board will not run the gate until two monitored photo eyes or edges are connected.
Read the number on the old board. BLGOC-2000, BLGOC-2200 or BLGOC-2400 all mean this is the replacement. A GOC-4200 or BLGOC-4200 is the AC-operator board for the ACTP715, UGP712 and CM-712 and is on its own page.
Specifications
| Part number | BLGOC-2400 (kit) |
|---|---|
| Replaces | BLGOC-2000, BLGOC-2200 |
| Fits | Platinum Access BLSL840, BLSL2250 (slide); BLSW814, BLSW1016 (swing) |
| Power | 24 VDC from the operator's switching supply, with battery backup |
| Entrapment protection | Requires two monitored photo eyes or edges to run |
| Condition | Genuine Platinum Access, new; circuit boards are non-returnable |
Which operators use it
| Operator | Type |
|---|---|
| BLSL840 | Brushless slide, 800 lb |
| BLSL2250 | Brushless slide, 2,200 lb |
| BLSW814 | Brushless swing |
| BLSW1016 | Brushless swing |
Ordered with it
Platinum loop rack board · WL-EDSRK wireless edge sensor kit · PRD-Kit radio kit
Is the board actually the problem?
The board is the most over-ordered part on a gate operator. Work down this list before you buy:
| Symptom | Check first |
|---|---|
| Operator dead, no lights on the board | Supply, the switching power supply and the batteries before the board |
| Board lights but refuses to run | The two monitored entrapment devices are missing or not learned — not a fault |
| Gate runs slowly or stops partway | The batteries, then the motor |
| Opens but will not close | A loop, photo eye or edge holding it open |
| Dead after a storm | The board — and fit surge protection with the new one |
After fitting
Learn the limits, connect and learn the two monitored entrapment devices, set the auto-close and force, and re-test the reversal in both directions.
Fit surge protection when you fit the board. Lightning and utility surges are the most common reason a gate operator or entry system board is replaced, and a new board on the same unprotected supply is at the same risk.
Related
Platinum slide gate operators · Platinum swing gate operators · Platinum accessories
Not sure which board you need? Send a photo of the number printed on your existing board to parts@gatehousesupplies.com or call 866-965-5599. We would rather confirm it than have you fit the wrong board.