Genuine Platinum Access GOC-4200 main control board (also labelled BLGOC-4200) — the control board for Platinum's ACTP715 and ACT-715 swing gate actuators, the UGP712 underground swing operator and the CM-712 swing operator, in their single (SK), primary / secondary (MSK) and unit-only (UNT) kits. It supersedes the GOC-4000 and the older GOC400 / ECU4000 control box board, and it needs at least one monitored photo eye connected to run.
Board or kit? This page is the board on its own. The GOC-4200 kit adds the GOC-4200LDR loop board and the 6-pin and 7-pin cables, which is what you need when replacing the whole board set in an old ECU4000 box. Brushless BLSL / BLSW operators use a different board, the BLGOC-2400.
Specifications
| Part number | GOC-4200 (also BLGOC-4200) |
|---|---|
| Replaces | GOC-4000, GOC400 (ECU4000 control box board) |
| Fits | Platinum Access ACTP715 / ACT-715 (SK, MSK), UGP712 (SK, MSK, UNT), CM-712 (SK, MSK, UNT) |
| Loop board | GOC-4200LDR, sold separately or in the kit |
| Entrapment protection | Requires at least one monitored photo eye |
| Condition | Genuine Platinum Access, new; circuit boards are non-returnable |
Which operators use it
| Operator | Kits |
|---|---|
| ACTP715 swing actuator | ACTP715-SK · ACTP715-MSK |
| UGP712 underground swing | UGP712-SK · UGP712-MSK · UGP712-UNT |
| CM-712 swing | CM-712-SK · CM-712-MSK · CM-712-UNT |
Ordered with it
GOC-4200LDR loop board · GOC-4200 board kit · PRD-Kit radio kit
Is the board actually the problem?
The board is the most over-ordered part on a gate operator. Work down this list before you buy:
| Symptom | Check first |
|---|---|
| Operator dead, no lights on the board | Supply, the transformer and the fuse before the board |
| Board lights but refuses to run | The monitored photo eye is missing or not learned — not a fault |
| Loops ignored | The GOC-4200LDR loop board and its cable, not the main board |
| One arm of a dual runs, the other does not | The secondary arm, its cable and the primary / secondary setting before the board |
| Dead after a storm | The board — and fit surge protection with the new one |
After fitting
Learn the limits on each arm, connect and learn the monitored photo eye, set the auto-close and force, and re-test the reversal in both directions.
Fit surge protection when you fit the board. Lightning and utility surges are the most common reason a gate operator or entry system board is replaced, and a new board on the same unprotected supply is at the same risk.
Related
Platinum swing gate operators · Platinum accessories
Not sure which board you need? Send a photo of the number printed on your existing board to parts@gatehousesupplies.com or call 866-965-5599. We would rather confirm it than have you fit the wrong board.