LiftMaster K41-0388-000MC Main Board with Battery Backup - Maxum JDC, RJDC, JHDC, TDC

(No reviews yet) Write a Review
SKU:
K41-0388-000MC
Availability:
In Stock

Liftmaster

$376.43
UPC:
012381218028
Condition:
New

Genuine LiftMaster K41-0388-000MC main board — the control board, with battery backup, for every LiftMaster Maxum industrial DC operator: the JDC, RJDC and JHDC jackshaft and hoist models and the TDC trolley. One board serves the whole platform, at every voltage and door weight.

What does change with the model. The main board is common, but the EMI board and transformer are voltage-specific and the bridge rectifier depends on the operator size. Check the voltage digit in your model number (1 = 120/240V, 4 = 480V) before ordering those.

Specifications

Part numberK41-0388-000MC
LiftMaster descriptionMain Board with Battery Backup, Maxum
FitsJDC, RJDC, JHDC and TDC — all Maxum operators
ConditionGenuine LiftMaster OEM, new

The other boards in a Maxum

PartFits
K41-0391-000 EMI boardAll Maxum, 120/240 VAC
K41-0390-000 EMI boardAll Maxum, 480 VAC
K41-0380-000 bridge rectifier700 and 1200 models
K41-0478-000 bridge rectifier2200 models
K41-0387-000 encoderEncoder with drive sprocket
K41-0395-000 control boxFront, back and hardware

Is the main board actually the problem?

SymptomCheck first
No response at all, no display on the wall controllerThe toroidal transformer for your weight and voltage, then the bridge rectifier
Operator dead after a lightning event or line surgeThe EMI board — K41-0391-000 (120/240 VAC) or K41-0390-000 (480 VAC) — then this board
Limits drift or the door overrunsThe K41-0387-000 encoder, not the board
Runs on mains, fails in a power cutThe backup batteries
Powers up but ignores every inputThis board
Burnt smell, scorching or a bulged capacitor on this boardThis board — replace it

After fitting

The board arrives unprogrammed. Set the open and close limits, relearn the transmitters, and re-test the entrapment protection devices before returning the door to service.

Fit surge protection at the same time. Storm damage is a leading cause of gate operator board failure. If this board died after a storm, the replacement is at the same risk unless the installation is protected.

Related

JDC, RJDC, JHDC parts · all Maxum parts

Not sure which board you need? Send a photo of your existing board to parts@gatehousesupplies.com or call 866-965-5599. We would rather confirm it than have you fit the wrong board.