Genuine LiftMaster K41-0388-000MC main board — the control board, with battery backup, for every LiftMaster Maxum industrial DC operator: the JDC, RJDC and JHDC jackshaft and hoist models and the TDC trolley. One board serves the whole platform, at every voltage and door weight.
What does change with the model. The main board is common, but the EMI board and transformer are voltage-specific and the bridge rectifier depends on the operator size. Check the voltage digit in your model number (1 = 120/240V, 4 = 480V) before ordering those.
Specifications
| Part number | K41-0388-000MC |
|---|---|
| LiftMaster description | Main Board with Battery Backup, Maxum |
| Fits | JDC, RJDC, JHDC and TDC — all Maxum operators |
| Condition | Genuine LiftMaster OEM, new |
The other boards in a Maxum
| Part | Fits |
|---|---|
| K41-0391-000 EMI board | All Maxum, 120/240 VAC |
| K41-0390-000 EMI board | All Maxum, 480 VAC |
| K41-0380-000 bridge rectifier | 700 and 1200 models |
| K41-0478-000 bridge rectifier | 2200 models |
| K41-0387-000 encoder | Encoder with drive sprocket |
| K41-0395-000 control box | Front, back and hardware |
Is the main board actually the problem?
| Symptom | Check first |
|---|---|
| No response at all, no display on the wall controller | The toroidal transformer for your weight and voltage, then the bridge rectifier |
| Operator dead after a lightning event or line surge | The EMI board — K41-0391-000 (120/240 VAC) or K41-0390-000 (480 VAC) — then this board |
| Limits drift or the door overruns | The K41-0387-000 encoder, not the board |
| Runs on mains, fails in a power cut | The backup batteries |
| Powers up but ignores every input | This board |
| Burnt smell, scorching or a bulged capacitor on this board | This board — replace it |
After fitting
The board arrives unprogrammed. Set the open and close limits, relearn the transmitters, and re-test the entrapment protection devices before returning the door to service.
Fit surge protection at the same time. Storm damage is a leading cause of gate operator board failure. If this board died after a storm, the replacement is at the same risk unless the installation is protected.
Related
JDC, RJDC, JHDC parts · all Maxum parts
Not sure which board you need? Send a photo of your existing board to parts@gatehousesupplies.com or call 866-965-5599. We would rather confirm it than have you fit the wrong board.