Genuine All-O-Matic ACPCB control board (All-O-Matic part 11009) — the control board for All-O-Matic's AC-motor gate operators built before the 2016 UL325 change: the SL-100AC and SL-150AC slide operators and the AC swing and overhead units of the same generation. It carries the limit inputs, loop and safety inputs, the radio terminals and the motor relays.
Pre-2016 or post-2016? Operators built from 2016 carry the ACPCB-UL board with the monitored entrapment inputs; this ACPCB is the earlier non-UL board. Read the number on the board and the year on the operator label before ordering — the two are not interchangeable.
Specifications
| Part number | ACPCB (11009) |
|---|---|
| All-O-Matic description | Control board, AC operators (non-UL, pre-2016) |
| Fits | SL-100AC, SL-150AC and other All-O-Matic AC operators built before 2016 |
| Post-2016 equivalent | ACPCB-UL |
| Condition | Genuine All-O-Matic, new |
Ordered with it
Prime-VD-1 loop detector · AOM Red Eye photo eye
Is the board actually the problem?
The board is the most over-ordered part on a gate operator. Work down this list before you buy:
| Symptom | Check first |
|---|---|
| Operator dead, no lights on the board | Supply, the transformer and the fuse before the board |
| Motor hums, gate does not move | The capacitor on an AC operator, not the board |
| Opens but will not close | A loop, photo eye or edge holding it open |
| Runs one direction only | The limit switches before the board |
| Dead after a storm | The board — and fit surge protection with the new one |
After fitting
Set the limits and the auto-close timer, then re-test every loop, photo eye and edge before returning the gate to service.
Fit surge protection when you fit the board. Lightning and utility surges are the most common reason a gate operator or entry system board is replaced, and a new board on the same unprotected supply is at the same risk.