Genuine LiftMaster CPSUN4G heavy-duty monitored through-beam photo eyes — the NEMA 4 version of LiftMaster's Commercial Protector System: an emitter and receiver pair in sealed housings that reverses a commercial door or stops a gate when the beam is broken. Up to 45 ft between the eyes, indoor or outdoor, monitored so the operator knows the eyes are connected and working. Black housing; the same device LiftMaster previously sold as the yellow CPS-UN4, covered by the same manual.
CPSUN4G, CPS-U or reflective? The CPS-U is the standard eye shipped with Logic 5.0 and medium-duty operators — NEMA 1, indoor, 30 ft. Choose the CPSUN4G when the eyes see washdown, weather or a wide opening (to 45 ft). Where you can only wire one side of the opening, the CPS-RPEN4 reflective eye needs power on one side only.
Specifications
| Part number | CPSUN4G (same device as CPS-UN4); UPC 012381183012 |
|---|---|
| Type | Monitored through-beam photo eye pair (emitter + receiver) — LiftMaster Monitored Entrapment Protection |
| Range | 7 to 45 ft |
| Enclosure | NEMA 4 — protects against direct water spray; indoor or outdoor |
| Indicators | Green LED on the emitter, yellow LED on the receiver |
| Wiring | 36 in leads, 1/2 in conduit fitting with sealing washer; 20 ga minimum field wire |
| Mounting | Heavy-duty housings and brackets included. Doors: no higher than 6 in above the floor. Gates: no higher than 27.5 in above grade |
| Colour | Black |
| Condition | Genuine LiftMaster, new |
Works with
| Operator | Note |
|---|---|
| LiftMaster commercial door operators — Logic 5, Logic 4, Logic 3 and Medium-Duty Logic (H, HJ, J, T, GT, GH, MH, MHS, MJ, MT, BMT, MGJ, HMJ, SD), FDC, FDCL, FDO, LGE | Direct connect. On Logic 4 / Logic 5 with more than one sensor, add the CPS3CARD |
| LiftMaster 2016 UL 325 gate operators — CSL24U, CSW24U, RSL12U, RSW12U, HCTDCU, LA400PKGU, LA412PKGU, LA500PKGU, CSW200501U / 101U, SL3000501U / 101U, SL585U, SL595U | Monitored entrapment input |
| Earlier LiftMaster gate operators — CSL24V, CSW24V, RSL12V, RSW12V, LA400, LA412, LA500 | Per LiftMaster's CPSUN4G manual |
Common questions
Is this the replacement for the CPS-UN4?
Yes — LiftMaster documents the CPS-UN4 and CPSUN4G in one manual. The CPSUN4G is the current black-housing version.
The door will not close and the operator shows a sensor fault.
Check alignment first: both LEDs steady means aligned. Then check the lens for dirt or sun on the receiver, then the wire run. A monitored eye that is unplugged or shorted stops the door by design.
Do I need both eyes?
Yes — sold as the emitter and receiver pair.
Related
CPS-U · CPS-RPEN4 reflective · CPS-OPEN4 · CPS3CARD · LMRRUL (gates) · LMTBUL (gates)
Not sure which eye your operator takes? Send the operator model to parts@gatehousesupplies.com or call 866-965-5599. We would rather confirm it than have you order twice.