Every maglock, electric gate lock and electric strike needs a regulated 12 or 24VDC power supply, and most need a way to release the lock from the secure side. GateHouse Supplies carries Altronix access power supplies and controller boards plus Alarm Controls and Camden request-to-exit buttons, the parts that complete a gate lock installation.
| Model | Input | Output | Lock outputs | Best for |
|---|---|---|---|---|
| Altronix AL600ULACM | 115VAC | 12/24VDC, 6A | 8 fused, fail safe/secure | Several maglocks or gate locks on one supply |
| Altronix AL600ULACMCB | 115VAC | 12/24VDC, 6A | 8 PTC, Class 2 | Same as AL600ULACM where Class 2 wiring is required |
| Altronix AL400ULACM | 115VAC | 12/24VDC, 4A | 8 fused, fail safe/secure | Multi-lock jobs with lighter current draw |
| Altronix AL175UL | 115VAC | 12/24VDC, 1.75A | 1 lock + 1 aux | One gate or door: lock plus keypad or reader |
| Altronix AL125UL | 115VAC | 12/24VDC, 1A | 2 Class 2 | One small maglock or strike |
| Altronix ACM8 | 12-24V AC/DC | Uses existing supply | 8 fused | Add lock control to a supply you already have |
| Altronix ACM8CB | 12-24V AC/DC | Uses existing supply | 8 PTC, Class 2 | Class 2 version of the ACM8 |
| Altronix ACM4 | 12-24V AC/DC | Uses existing supply | 4 fused | Smaller jobs, 2 to 4 locks |
| Model | Button | Timer | Best for |
|---|---|---|---|
| Alarm Controls TS-2 | 2 in. green square push button | None | Standard single gang exit button |
| Alarm Controls TS-2T | 2 in. green square, illuminated | Electronic, 2-45 s | Holds the lock open long enough to walk through |
| Alarm Controls TS-14 | 1-1/2 in. green mushroom | Pneumatic, 2 s-1 min | Heavy duty, code-required egress |
| Alarm Controls TS-9 | Narrow plate, illuminated | None | Gate posts, mullions, narrow frames |
| Camden CM-221/46 | Touchless wave sensor, IP65 | 0.5-20 s | Touch-free exit, indoor or outdoor |
| Camden CM-221M/46 | Touchless + manual override, IP65 | 0.5-20 s | Touch-free with a backup push button |
Can I power a maglock from my gate operator? Some operator boards have an accessory output, but it is usually limited in current and may not be battery backed. A dedicated lock power supply with battery backup is the reliable choice, triggered by the operator, keypad or access control panel.
Do I need a timer on the exit button? Without a timer, the lock relocks as soon as the button is released. A timed button (TS-2T, TS-14) or a power supply with an adjustable relay keeps the lock released long enough to walk through.
Which exit button for an outdoor gate? The Camden CM-221/46 and CM-221M/46 are IP65 rated for outdoor use. The narrow TS-9 fits a gate post or mullion.