The Liftmaster LA400PKGUL is a top-of-the-line choice for residential dual swing gate openers. This liftmaster dual gate opener provides the reliability and performance needed for smooth gate operation. If you're in the market for a swing gate opener that offers both power and efficiency, the la400pkgul is designed to meet your needs. Its ease of installation and user-friendly la400 manual make it an excellent choice for DIY enthusiasts and professionals alike. Enhance the functionality of your property's entrance with the liftmaster swing gate opener. The la400 liftmaster is equipped with advanced features that ensure secure access to your home while delivering the convenience of remote operation. As a dual swing gate opener, it's ideally suited for double gate systems, making it a versatile choice for various gate designs. The robust engineering of the liftmaster la400pkgul ensures longevity, and its compatibility with the la400pkgu makes it a smart investment for gate security. For those requiring a liftmaster double gate opener, the liftmaster la400pkgul stands out for its performance and durability. It's a testament to Liftmaster's commitment to quality, with the liftmaster la400 residential dc linear gate operator being a testament to their attention to functionality and user satisfaction. Lastly, the la400pkgul manual provides clear instructions, simplifying maintenance and troubleshooting for years of reliable use. Trust in the liftmaster la400 dual gate opener to keep your property secure and accessible with state-of-the-art technology and proven dependability.

 

LiftMaster LA400 for two piece bi parting gates

LiftMaster LA400 - 24VDC-Powered Residential and Light Commercial Linear Gate Operator with 2 arms, control box and built in receiver and safety photo eye
Updated unit complies with new UL325 code revised Aug 2018
System now requires monitored secondary entrapment devices
unit will include LMRRU safety photo eye
2 yr manufactures warranty

Now with MyQ technology
Use with Security 2.0 remotes like 892LT, 893max, 890max or 894LT sold separately.
Use optional 828LM Internet gateway to connect to internet/smartphones

Download LA400 Manual


Download LA400 Brochure
 
 
Features
One of our most popular swing gate operators just got even better in delivering unsurpassed performance and secure access to your property.

Access your property like never before. With MyQ Technology you can monitor and control your gate from anywhere and get in quickly and securely with the built-in interference eliminating Security+ 2.0 radio. Best in class power management technology extends battery backup for up to 97 days* without recharging, providing greater security and reliability in your LiftMaster. No one else can offer you that peace of mind.


Connectivity


  • MyQ Technology enables you to securely monitor and control your gate operator and houselights with your smartphone for greater peace of mind.
  • Alerts can be received as email or pop-up (push) notifications on your mobile device so that you always know the status of your gate operator.
  • MyQ Mobile App is a free download with no annual activation fee.


Performance


  • Battery Backup safeguards your property by providing up to 400 cycles* or up to 97 days* of standby power when the power is down.
  • Solar Ready Ultra Reliable System delivers power when you need it most to operate the LiftMaster gate and is extremely power efficient at all other times to maximize solar performance. Home owners may qualify for 30% solar tax credit.
  • Heavy-Duty Cast Aluminum Housing DC Motor powerful enough to perform in the most demanding applications. Soft start/stop operation extends operator and hardware life for heavy-duty gate use.
  • Gate Size rated for gates up to 16 ft. in length or weighing up to 850 lbs..


Safety and Security

  • Security+ 2.0™ Patented Multi-Frequency Secure Radio Technology virtually eliminates interference and offers 2X the range of standard remotes so you can access your home quickly and safely.
  • Safety Inputs provided for the addition of safety reversing devices. Each entrapment point should be protected with its own device.
  • UL/cUL Listed tested to the most stringent industry guidelines. 
Capacity




Dimensions



 
Liftmaster LA400 Error codes
 
Error Code                        Solution

31 Main control board has experienced an internal failure. Disconnect all power, wait 15 seconds, then reconnect power (reboot). If issue continues, replace main control board.
32 Linear Drive Disengaged (Arm 1) Disengage then re-engage arm. Check wiring and connections.
33 Linear Drive Disengaged (Arm 2)
35 Max-Run-Time Exceeded Error Check for an obstruction, then reprogram the limits.
36 Product ID Error Was the control board just replaced? If so, erase limits, enter limit setup mode and set limits. If not, disconnect all power, wait 15 seconds, then reconnect power before changing product ID harness.
37 Product ID Failure Unplug product ID harness then plug back in. Disconnect all power, wait 15 seconds, then reconnect power before replacing product ID harness.
38 Hard Stop Limit (Arm 1) Limit may be set too tightly against a non-resilient hard stop (re-adjust limit). Operator may be at end of travel (re-adjust mounting).
39 Hard Stop Limit (Arm 2)
40 Battery overvoltage Too much voltage on the battery. Check harness. Make sure there is NOT a 24V battery on a 12V system.
41 Battery overcurrent Possible short of the battery charge harness. Check harness. Make sure you do NOT have a 12V battery on a 24V system.
42 No battery at boot up Check battery connections and installation. Replace batteries if depleted to less than 20V on a 24V system or less than 10V on a 12V system. Make sure there is NOT a single 12V battery on a 24V system
43 Exit Loop Error Failure or missing loop (SHORT or OPEN - LiftMaster Plug-in Loop Detector only) Check loop wiring throughout connection. May be a short in the loop, or an open connection in the loop. 
44 Shadow Loop Error
45 Interrupt Loop Error
46 Wireless edge battery low Replace batteries in wireless edge. 
51 Pass-point not detected (Arm 1) Check yellow pass-point wiring. If limits are not accurate, reprogram. 
52 Pass-point not detected (Arm 2)

53  Brownout occurred AC/DC board supply dipped below allowable level. Review power supply and wiring. If rebooting, ensure enough time for discharge of power to force a fresh boot.
YES

54  Wireless Second Operator Communication Error Check the second operator for power. If OFF, restore power and try to run the system. If powered, deactivate the wireless feature and then re-learn the second operator.
YES

60 Minimum number of monitored entrapment protection devices not installed. Review monitored entrapment protection device connections. This swing gate operator will operate only after installation of a minimum of one external safety device in either the open or close direction.
61 CLOSE EYE/INTERRUPT held more than 3 minutes
Check wired input on main control board; check for alignment or obstruction.
62 CLOSE EDGE held more than 3 minutes
63 OPEN EYE/EDGE held more than 3 minutes
64 CLOSE EYE/INTERRUPT held more than 3 minutes
Check wired input on expansion board; check for alignment or obstruction.
65 CLOSE EYE/EDGE held more than 3 minutes
66 OPEN EYE/EDGE held more than 3 minutes
67 Wireless edge triggered more than 3 minutes Check wired input for wiring issue or obstruction.
68 Wireless edge loss of monitoring Check wireless edge inputs.

69 Wireless edge triggered IF an obstruction occurred, no action required. If an obstruction did NOT occur, check inputs and wiring.
70 CLOSE EYE/INTERRUPT triggered, causing reversal, preventing close, or resetting TTC IF an obstruction occurred, no action required. If an obstruction did NOT occur, check alignment, inputs, and wiring on main control board

71 CLOSE EDGE triggered, causing reversal, NO preventing close, or canceling TTC
72 OPEN EYE/EDGE triggered, causing reversal or preventing opening
73 CLOSE EYE/INTERRUPT triggered, causing reversal, preventing close, or resetting TTC IF an obstruction occurred, no action required. If an obstruction did NOT occur, check alignment, inputs, and wiring on expansion board.

74 CLOSE EYE/EDGE triggered, causing reversal and preventing close or canceling TTC
75 OPEN EYE/EDGE triggered, causing reversal or preventing opening
80 Close input (EYE/EDGE) communication fault from other operator Check inputs and communication method between operators, either wired bus or radio. Ensure operator is powered. May have to erase the wireless communication and reprogram the two operators.
81 Open input (EYE/EDGE) communication fault from other operator
82 Close input (EYE/EDGE) communication fault (expansion board) Check the connections between the main board and the expansion board.
83 Open input (EYE/EDGE) communication fault (expansion board)

84 Non-monitored device detected on the wireless safety system Non-monitored contact closure devices are not supported. Make sure connected devices are monitored. Check edges for proper orientation and resistive end cap connection.
91 Force Reversal (Operator 1) Check for obstruction. If no obstruction, check that the mechanical assembly is engaged and free to move. See section on Limit and Force Adjustment, and Obstruction Test.
92 Force Reversal (Operator 2)
93 RPM / STALL Reversal (Operator 1) Check for obstruction. If no obstruction, check the operator wiring and that the mechanical assembly is engaged and free to move. Replace APE assembly.
94 RPM / STALL Reversal (Operator 2)
99 Normal Operation No action required