The LA400DCS Secondary 24 VDC Actuator Arm is an innovative solution designed specifically for dual swing gate applications, making it a perfect choice for homeowners and businesses seeking both reliability and performance. Since its redesign in August 2014, this state-of-the-art actuator arm combines enhanced functionality with modern aesthetics to seamlessly integrate into your gate system.
This actuator arm stands out with its advanced MyQ technology, allowing users to monitor and control their gates remotely. This smart feature offers unparalleled convenience, ensuring that your property remains secure while providing easy access to authorized users. Whether you are at home or on the go, you can effortlessly operate your gate at the touch of a button.
The LA400DCS comes fully equipped with a junction box and a 40-foot cable, making installation straightforward and hassle-free. The inclusion of these essential components ensures that you have everything needed to set up your gate system quickly and efficiently. The detailed installation manual is available for reference, guiding you through the process step by step, whether you're a DIY enthusiast or prefer professional assistance.
Crafted from durable materials, the LA400DCS is built to withstand various weather conditions, ensuring long-lasting performance and minimal maintenance. Its robust design not only enhances the gate's operational reliability, but also adds elegance to any entrance.
Ideal for residential driveways or commercial properties, the LA400DCS Secondary 24 VDC Actuator Arm represents the perfect fusion of functionality, security, and technological advancement, making it an essential addition to your gate control system. Experience the future of gate automation with this premium actuator arm that is engineered to exceed expectations.
LA400DCS arm for dual swing gate applications (new style since 08-2014)
(junction box & 40' cable included)
Now with MyQ technology
Liftmaster LA400DCS Installation Manual (click here)
31 Main control board has experienced an internal failure. Disconnect all power, wait 15 seconds, then reconnect power (reboot). If issue continues, replace main control board.
32 Linear Drive Disengaged (Arm 1) Disengage then re-engage arm. Check wiring and connections.
33 Linear Drive Disengaged (Arm 2)
35 Max-Run-Time Exceeded Error Check for an obstruction, then reprogram the limits.
36 Product ID Error Was the control board just replaced? If so, erase limits, enter limit setup mode and set limits. If not, disconnect all power, wait 15 seconds, then reconnect power before changing product ID harness.
37 Product ID Failure Unplug product ID harness then plug back in. Disconnect all power, wait 15 seconds, then reconnect power before replacing product ID harness.
38 Hard Stop Limit (Arm 1) Limit may be set too tightly against a non-resilient hard stop (re-adjust limit). Operator may be at end of travel (re-adjust mounting).
39 Hard Stop Limit (Arm 2)
40 Battery overvoltage Too much voltage on the battery. Check harness. Make sure there is NOT a 24V battery on a 12V system.
41 Battery overcurrent Possible short of the battery charge harness. Check harness. Make sure you do NOT have a 12V battery on a 24V system.
42 No battery at boot up Check battery connections and installation. Replace batteries if depleted to less than 20V on a 24V system or less than 10V on a 12V system. Make sure there is NOT a single 12V battery on a 24V system
43 Exit Loop Error Failure or missing loop (SHORT or OPEN - LiftMaster Plug-in Loop Detector only) Check loop wiring throughout connection. May be a short in the loop, or an open connection in the loop.
44 Shadow Loop Error
45 Interrupt Loop Error
46 Wireless edge battery low Replace batteries in wireless edge.
51 Pass-point not detected (Arm 1) Check yellow pass-point wiring. If limits are not accurate, reprogram.
52 Pass-point not detected (Arm 2)
53 Brownout occurred AC/DC board supply dipped below allowable level. Review power supply and wiring. If rebooting, ensure enough time for discharge of power to force a fresh boot.
YES
54 Wireless Second Operator Communication Error Check the second operator for power. If OFF, restore power and try to run the system. If powered, deactivate the wireless feature and then re-learn the second operator.
YES
60 Minimum number of monitored entrapment protection devices not installed. Review monitored entrapment protection device connections. This swing gate operator will operate only after installation of a minimum of one external safety device in either the open or close direction.
61 CLOSE EYE/INTERRUPT held more than 3 minutes
Check wired input on main control board; check for alignment or obstruction.
62 CLOSE EDGE held more than 3 minutes
63 OPEN EYE/EDGE held more than 3 minutes
64 CLOSE EYE/INTERRUPT held more than 3 minutes
Check wired input on expansion board; check for alignment or obstruction.
65 CLOSE EYE/EDGE held more than 3 minutes
66 OPEN EYE/EDGE held more than 3 minutes
67 Wireless edge triggered more than 3 minutes Check wired input for wiring issue or obstruction.
68 Wireless edge loss of monitoring Check wireless edge inputs.
69 Wireless edge triggered IF an obstruction occurred, no action required. If an obstruction did NOT occur, check inputs and wiring.
70 CLOSE EYE/INTERRUPT triggered, causing reversal, preventing close, or resetting TTC IF an obstruction occurred, no action required. If an obstruction did NOT occur, check alignment, inputs, and wiring on main control board
71 CLOSE EDGE triggered, causing reversal, NO preventing close, or canceling TTC
72 OPEN EYE/EDGE triggered, causing reversal or preventing opening
73 CLOSE EYE/INTERRUPT triggered, causing reversal, preventing close, or resetting TTC IF an obstruction occurred, no action required. If an obstruction did NOT occur, check alignment, inputs, and wiring on expansion board.
74 CLOSE EYE/EDGE triggered, causing reversal and preventing close or canceling TTC
75 OPEN EYE/EDGE triggered, causing reversal or preventing opening
80 Close input (EYE/EDGE) communication fault from other operator Check inputs and communication method between operators, either wired bus or radio. Ensure operator is powered. May have to erase the wireless communication and reprogram the two operators.
81 Open input (EYE/EDGE) communication fault from other operator
82 Close input (EYE/EDGE) communication fault (expansion board) Check the connections between the main board and the expansion board.
83 Open input (EYE/EDGE) communication fault (expansion board)
84 Non-monitored device detected on the wireless safety system Non-monitored contact closure devices are not supported. Make sure connected devices are monitored. Check edges for proper orientation and resistive end cap connection.
91 Force Reversal (Operator 1) Check for obstruction. If no obstruction, check that the mechanical assembly is engaged and free to move. See section on Limit and Force Adjustment, and Obstruction Test.
92 Force Reversal (Operator 2)
93 RPM / STALL Reversal (Operator 1) Check for obstruction. If no obstruction, check the operator wiring and that the mechanical assembly is engaged and free to move. Replace APE assembly.
94 RPM / STALL Reversal (Operator 2)
99 Normal Operation No action required