Genuine Nice Apollo 1050US universal control board — the UL325 (2018) version of Apollo's LCD-programmed smart board, with the monitored entrapment-device inputs required for new installations in the US. It runs the current Apollo swing and slide operators, single or dual (primary / secondary), on AC or solar, and takes the plug-in Nice receiver. The international 1050I is the same board family without the UL325 monitored inputs.
1050US or 1050I? For a UL325-compliant site, or any new installation, order the 1050US and fit the required entrapment devices: two monitored sensors on a slide gate, and on a swing gate two unless there is no entrapment risk in one direction. The board will not run the gate until they are connected. For a like-for-like swap on an operator already running a 1050I, the 1050I is the board.
Specifications
| Part number | 1050US |
|---|---|
| Nice Apollo description | Universal smart control board, UL325 2018 |
| Display | 2-line LCD with programming, navigation and open / close / stop buttons |
| Receiver | Plug-in Nice receiver, up to 1,000 rolling-code transmitters |
| Power | 12–24 VDC; AC transformer or solar panel up to 30 W; battery charging |
| Configuration | Single or dual (primary / secondary) |
| Condition | Genuine Nice Apollo, new |
Which operators use it
| Type | Models |
|---|---|
| Slide | 7251 (7200), 7351 (7300), 7000, 7100, 8300SL, 8500SL, NT-M12ETL, NT-H12ETL |
| Swing | 1550 (1551), 1650, 3500, 4300SW, 4500SW, 1724, 1824, NT-T5, NT-T7, Titan 12L1 |
Older 7200 operators: the 1050 board runs them but does not mount in the original box, and a 40BS13 sprocket is needed. Send us the operator's serial number before ordering for one of those.
Ordered with it
APOW3 24 VAC transformer · see the 7251 parts and 7351 parts pages for the rest of the operator
Is the board actually the problem?
The board is the most over-ordered part on a gate operator. Work down this list before you buy:
| Symptom | Check first |
|---|---|
| Board dead, no display | Battery voltage first, then the transformer or solar output at the board |
| Board lights but refuses to run | The monitored entrapment devices are missing or not learned — not a fault |
| Gate runs slowly, stops partway, or only in daylight on a solar site | The battery, then the panel output |
| Display shows an error code | Look the code up in the 1050 manual first — most point at a photocell, loop or limit |
| Remotes do nothing, the buttons on the board work | The plug-in receiver, then the remotes |
| Failed after a storm | The board — check the receiver too, and fit surge protection |
After fitting
Set the operator type and limits, learn the monitored entrapment devices, pair the receiver and remotes, then re-test the reversal in both directions.
Fit surge protection when you fit the board. Lightning and utility surges are the most common reason a gate operator or entry system board is replaced, and a new board on the same unprotected supply is at the same risk.