Genuine DoorKing 1834-010 control board — the main board for the DoorKing 1834 telephone entry system, 1834-080, 1834-084 only. The 1834 has two boards across its model range and they are not interchangeable.
A $1,500 mistake to avoid. The 1834-010 fits the 1834-080 and 1834-084. The 1834-009 fits the 1834-089 and 1834-090. Read the model number on the label inside the door, or the number on the board itself, before ordering. You are on the 1834-010 page; the other board is the 1834-009.
Ships without the memory chip. The 3,000-name directory lives on the plug-in 1834-157 chip. Move yours across and the programming carries over. The 1891-010 single-line display is also separate.
Specifications
| Part number | 1834-010 |
|---|---|
| DoorKing description | PCB Modem Programmable, Electronic Directory |
| Fits | DoorKing 1834 — 1834-080, 1834-084 |
| Includes | Board only — no memory chip, no display |
| Condition | Genuine DoorKing OEM, new |
Is the board actually the problem?
| Symptom | Check first |
|---|---|
| Unit dead, no display | Transformer and power wiring before the board |
| Display alive but the unit will not dial or answer | The phone line at the terminals — confirm dial tone with a handset first |
| Directory or codes lost | The 1834-157 memory chip, not the board |
| Display scrambled or dead, unit otherwise working | The 1891-010 display |
| Powers up but ignores everything; relays never fire | The board |
| Talks and dials, but the door relay never fires | The relay wiring and the strike or maglock supply, then the board |
| Failed after a storm | Surge damage on the phone line or power — the board, and fit phone-line surge protection with the replacement |
After fitting
Fit your existing memory chip to the new board before powering up; the directory and codes live on the chip, not the board. Then confirm the system settings — talk time, relay strike time, tone-open codes — against your records before handing the system back.
Related
1834 parts · all DoorKing telephone entry parts
Not sure which board you need? Send a photo of your existing board to parts@gatehousesupplies.com or call 866-965-5599. We install and service DoorKing telephone entry systems and would rather confirm it than have you fit the wrong board. Since 1993.