Genuine LiftMaster MA001 control board — the circuit board for the LiftMaster Mega Arm MA and MAT barrier gate operators. LiftMaster also numbers it K79-60166; both numbers refer to this board.
How to identify it. Read the board in the operator cabinet: MA001 or K79-60166 on the label. If the operator is dead with power confirmed, or it powers up but ignores every input, this is the usual part.
Specifications
| Part number | MA001 |
|---|---|
| Also numbered | K79-60166 |
| Fits | LiftMaster Mega Arm MA and MAT |
| Condition | Genuine LiftMaster OEM, new |
The other parts in the Mega Arm
| Part | Notes |
|---|---|
| MA002 | Limit switch assembly |
| MA003 | Motor, 1/2 HP, 24 VDC |
| MBAT | Battery, Yuasa NP7-12, 12V 7AH |
| MA005 | Gear reducer, 60:1 |
Is the board actually the problem?
| Symptom | Check first |
|---|---|
| Operator dead, no board lights | Incoming power and the battery before the board |
| Arm runs slowly or dies in a power cut | The MBAT battery |
| Arm overruns or stops short | The MA002 limit switch assembly, not the board |
| Board lights but the arm does not move | The MA003 motor and the MA005 gear reducer |
| Powers up but ignores every input | The board |
| Failed after a storm | Surge damage — the board |
After fitting
The new board arrives unprogrammed. Set the travel limits and force, relearn every remote and transmitter, and re-enter timer, loop and accessory settings before returning the gate to service. Re-test every entrapment protection device before handing the gate back.
Fit surge protection at the same time. Storm damage is a leading cause of gate operator board failure. If this board died after a storm, the replacement is at the same risk unless the installation is protected.
Related
LiftMaster Mega Arm parts · safety equipment, sensors & loops
Not sure which board you need? Send a photo of your existing board to parts@gatehousesupplies.com or call 866-965-5599. We would rather confirm it than have you fit the wrong board.