LA400XL20W Solar Package

(No reviews yet)
SKU:
LA400XL20W
Availability:
In Stock

Product Price: $2,126.31
UPC:
LA400XL20W
Condition:
New
LA400XL20W Package
This package includes
  • 24VDC Solar Residential Linear Actuator
  • XL Solar Control Box, (For use with 33AH Battery)
  • (2) 33AH Batteries with Tray
  • 20 Watt Solar Panel Kit, (Includes (2) 10W panels)
  • Solar Harness
  • Retro-Reflective Photo Eye

For secondary arm for dual gates order LA400DCS


Solar Powered Residential Gate Operator The LA400 is a solar powered residential swing gate operator with EverCharge Power Management System - it delivers power when needed most for opening the gate and minimizes power consumption at all other times for best solar performance. Its DC motor provides soft start/soft stop operation. This promotes longer gate and operator life, as well as dependable performance. The LA400 is capable of operating gates up to 16 ft. long and weighing up to 550 lbs. This model is UL325-compliant for Class I. An on-board radio receiver is included with the LA400. Exclusive from Chamberlain, this provides a single remote control solution for gates and additional access points. Standard Features: Solar panel* * NOTE: Additional panels may be required depending on single or dual gate application, geographical location, number of cycles per day, and accessories used. Refer to solar cycle chart for more details. On-board radio receiver DC motor - slow start/stop operation Inherent obstruction sensing External obstruction sensing Control inputs Bi-part relay Timer-to-close LED indicators Electronic limit system Keyed manual disconnect 2-year warranty * solar-friendly accessories recommended Optional Accessories: LD7LP 10-30 VAC/DC low power loop detector SGLOCK12V Solenoid gate lock LM202 Vehicle sensing driveway probe 50-220 The Protector System safety sensors
 
 
 
     
     
 
Features
LA412XL20W - Includes
  • 24VDC Solar Residential Linear Actuator
  • XL Solar Control Box, (For use with 33AH Battery)
  • (2) 33AH Batteries with Tray
  • 20 Watt Solar Panel Kit, (Includes (2) 10W panels)
  • Solar Harness
  • Retro-Reflective Photo Eye 
Liftmaster LA400 Error codes
 
Error Code                        Solution

31 Main control board has experienced an internal failure. Disconnect all power, wait 15 seconds, then reconnect power (reboot). If issue continues, replace main control board.
32 Linear Drive Disengaged (Arm 1) Disengage then re-engage arm. Check wiring and connections.
33 Linear Drive Disengaged (Arm 2)
35 Max-Run-Time Exceeded Error Check for an obstruction, then reprogram the limits.
36 Product ID Error Was the control board just replaced? If so, erase limits, enter limit setup mode and set limits. If not, disconnect all power, wait 15 seconds, then reconnect power before changing product ID harness.
37 Product ID Failure Unplug product ID harness then plug back in. Disconnect all power, wait 15 seconds, then reconnect power before replacing product ID harness.
38 Hard Stop Limit (Arm 1) Limit may be set too tightly against a non-resilient hard stop (re-adjust limit). Operator may be at end of travel (re-adjust mounting).
39 Hard Stop Limit (Arm 2)
40 Battery overvoltage Too much voltage on the battery. Check harness. Make sure there is NOT a 24V battery on a 12V system.
41 Battery overcurrent Possible short of the battery charge harness. Check harness. Make sure you do NOT have a 12V battery on a 24V system.
42 No battery at boot up Check battery connections and installation. Replace batteries if depleted to less than 20V on a 24V system or less than 10V on a 12V system. Make sure there is NOT a single 12V battery on a 24V system
43 Exit Loop Error Failure or missing loop (SHORT or OPEN - LiftMaster Plug-in Loop Detector only) Check loop wiring throughout connection. May be a short in the loop, or an open connection in the loop. 
44 Shadow Loop Error
45 Interrupt Loop Error
46 Wireless edge battery low Replace batteries in wireless edge. 
51 Pass-point not detected (Arm 1) Check yellow pass-point wiring. If limits are not accurate, reprogram. 
52 Pass-point not detected (Arm 2)

53  Brownout occurred AC/DC board supply dipped below allowable level. Review power supply and wiring. If rebooting, ensure enough time for discharge of power to force a fresh boot.
YES

54  Wireless Second Operator Communication Error Check the second operator for power. If OFF, restore power and try to run the system. If powered, deactivate the wireless feature and then re-learn the second operator.
YES

60 Minimum number of monitored entrapment protection devices not installed. Review monitored entrapment protection device connections. This swing gate operator will operate only after installation of a minimum of one external safety device in either the open or close direction.
61 CLOSE EYE/INTERRUPT held more than 3 minutes
Check wired input on main control board; check for alignment or obstruction.
62 CLOSE EDGE held more than 3 minutes
63 OPEN EYE/EDGE held more than 3 minutes
64 CLOSE EYE/INTERRUPT held more than 3 minutes
Check wired input on expansion board; check for alignment or obstruction.
65 CLOSE EYE/EDGE held more than 3 minutes
66 OPEN EYE/EDGE held more than 3 minutes
67 Wireless edge triggered more than 3 minutes Check wired input for wiring issue or obstruction.
68 Wireless edge loss of monitoring Check wireless edge inputs.

69 Wireless edge triggered IF an obstruction occurred, no action required. If an obstruction did NOT occur, check inputs and wiring.
70 CLOSE EYE/INTERRUPT triggered, causing reversal, preventing close, or resetting TTC IF an obstruction occurred, no action required. If an obstruction did NOT occur, check alignment, inputs, and wiring on main control board

71 CLOSE EDGE triggered, causing reversal, NO preventing close, or canceling TTC
72 OPEN EYE/EDGE triggered, causing reversal or preventing opening
73 CLOSE EYE/INTERRUPT triggered, causing reversal, preventing close, or resetting TTC IF an obstruction occurred, no action required. If an obstruction did NOT occur, check alignment, inputs, and wiring on expansion board.

74 CLOSE EYE/EDGE triggered, causing reversal and preventing close or canceling TTC
75 OPEN EYE/EDGE triggered, causing reversal or preventing opening
80 Close input (EYE/EDGE) communication fault from other operator Check inputs and communication method between operators, either wired bus or radio. Ensure operator is powered. May have to erase the wireless communication and reprogram the two operators.
81 Open input (EYE/EDGE) communication fault from other operator
82 Close input (EYE/EDGE) communication fault (expansion board) Check the connections between the main board and the expansion board.
83 Open input (EYE/EDGE) communication fault (expansion board)

84 Non-monitored device detected on the wireless safety system Non-monitored contact closure devices are not supported. Make sure connected devices are monitored. Check edges for proper orientation and resistive end cap connection.
91 Force Reversal (Operator 1) Check for obstruction. If no obstruction, check that the mechanical assembly is engaged and free to move. See section on Limit and Force Adjustment, and Obstruction Test.
92 Force Reversal (Operator 2)
93 RPM / STALL Reversal (Operator 1) Check for obstruction. If no obstruction, check the operator wiring and that the mechanical assembly is engaged and free to move. Replace APE assembly.
94 RPM / STALL Reversal (Operator 2)
99 Normal Operation No action required